xPower | 24.7KW | Model | MW5 Series |
---|---|---|---|
Environment | Scrap Yard | Quality | Grade A |
Lifting Capacity | 1500-1800 Kg | Machine Weght | 4500 Kg |
Highlight | large industrial magnets,rare earth magnets |
No. | Model | Power(KW) | Lifting Capacity ( scrap steel volume≥1.2T/M3) | machine weight(KG) |
1 | MW5-70L/1 | 3.2 | 100-120 | 500 |
2 | MW5-90L/1 | 5.6 | 200-250 | 7800 |
3 | MW5-110L/1 | 7.0 | 400-450 | 1250 |
4 | MW5-130L/1 | 11.9 | 600-700 | 2050 |
5 | MW5-150L/1 | 15.6 | 900-1100 | 2700 |
6 | MW5-165L/1 | 19.8 | 1100-1350 | 3400 |
7 | MW5-180L/1 | 22.4 | 1350-1600 | 4100 |
8 | MW5-185L/1 | 24.7 | 1500-1800 | 4500 |
9 | MW5-210L/1 | 27.3 | 1600-2200 | 6800 |
10 | MW5-240L/1 | 32.6 | 2200-2850 | 9000 |
MW electromagnet is widely used in smelt, casting and transportation department. It is a tool for conducting magnetic objects for carrying steel plate, steel casting , steel ingot, ingot, scrap iron and steel.
MW electromagnet is supporting the use of controlling equipment,cable reel and electronic weighing apparatus. It can effectively control electromagnet suction ,discharge and display weight value.
It has safe and reliable use.
Care and Maintenanc
-
Should regularly check whether there are cracks in the solenoid enclosure.
If it is found that cracks should be welded in time.
2, Each class before use to check whether the normal connectors and cables
Found abnormal should be processed in a timely manner
3, After long-term use, the insulation resistance of the electromagnet will drop
Please use 500V shake table to measure the thermal state of the electromagnet insulation resistance, should be more than 1M or more, or should be repaired in time
4, The chain and a pin used for a long time, found that more than 10% wear should be replaced
5 , After long-term use, the electromagnet is found to decrease the suction, and the DC resistance of the coil should be checked. If the rated value is not reached, the coil of the electromagnet should be replaced.
6, Magnet for many years after the use of magnetic pole ground. If the height of magnetic and non-magnetic plate h less than 10 mm, should replace the pole